You
are here - Structural
Repair > Wall Ties >
Types of Wall Ties > Spiro
Remedial Ties - Installation Procedure |
Spiro Remedial Ties
INSTALLATION PROCEDURE
| (view Specification) INSTALLATION PROCEDURE | |
| 1.) Drill a 10mm diameter hole through the masonry to a depth of 55mm in the inner leaf. Remove all dust and debris from the hole. | ![]() |
| 2.) Inject a quantity of Resin into the inner leaf hole, via a resin extension tube. Insert the tie into the resin and push firmly home. When the resin has set, a pull test can be undertaken where appropriate. Details of resin setting times are published in the Resin data sheets. | ![]() |
| 3.) To finish the outer leaf, inject the resin into the outer leaf as above until the hole is full. | ![]() |
| 4.) Make good the hole with matching mortar or mastic. | ![]() |
| Availability: |
|
|
|
| Packing: | |
|
|